Ripple compensator fatigue test

Fatigue life design of bellows compensator According to the failure type and cause analysis, the plane stability, circumferential stability and corrosion resistance of bellows are related to its displacement, namely fatigue life. Too low fatigue life will lead to bellows stability and corrosion resistance decline. According to the test and use experience, the fatigue life of bellows used in heating engineering should not be less than 1000 times.